Optical characterization of the BICEP array 150 and 220/270GHz CMB polarimeters in the 2026 season
M. Izquierdo Poza, P. A. R. Ade, Z. Ahmed, M. Amiri, D. Barkats, R. Basu Thakur, C. A. Bischoff, D. Beck, J. J. Bock, V. Buza, B. Cantrall, J. R. Cheshire IV, J. Connors, J. Cornelison, M. Crumrine, A. J. Cukierman, E. Denison, L. Duband, M. A. Echter, M. Eiben, B. D. Elwood, S. Fatigoni, J. P. Filippini, A. Fortes, M. Gao, C. Giannakopoulos, N. Goeckner-Wald, D. C. Goldfinger, J. A. Grayson, A. Greathouse, P. K. Grimes, M. Halpern, S. Henderson, T. D. Hoang, J. Hubmayr, H. Hui, K. D. Irwin, M. Izquierdo Poza, J. H. Kang, K. S. Karkare, S. Kefeli, J. M. Kovac, C. Kuo, K. Lasko, K. Lau, M. Lautzenhiser, T. Liu, S. C. Mackey, N. Maher, K. G. Megerian, L. Minutolo, L. Moncelsi, Y. Nakato, H. T. Nguyen, R. O’Brient, S. N. Paine, A. Patel, M. A. Petroff, A. R. Polish, T. Prouve, C. Pryke, C. D. Reintsema, T. Romand, M. Salatino, A. Schillaci, B. Schmitt, B. Singari, A. Soliman, T. St. Germaine, A. Steiger, B. Steinbach, R. Sudiwala, K. L. Thompson, C. Tucker, A. D. Turner, C. Verg`es, A. G. Vieregg, A. Wandui, A. C. Weber, J. Willmert, W. L. K. Wu, H. Yang, C. Yu, L. Zeng, C. Zhang, S. Zhang
arXiv:2608.25012v1 Announce Type: new
Abstract: BICEP Array (BA) is the current-generation instrument in the BICEP series of small-aperture, on-axis refracting telescopes at the South Pole, designed to constrain the tensor-to-scalar ratio $r$ through degree-scale measurements of B-mode polarization in the cosmic microwave background (CMB). As BA pushes to deeper sensitivity, control of instrumental systematics, and beam shape mismatch between the co-located orthogonally polarized detectors in particular, has become an increasingly important factor in translating raw sensitivity into a robust constraint on $r$. In these proceedings we report on the 2026 far field beam mapping (FFBM) campaign, which used a thermal chopped source to characterize the BA2 (150~GHz) and BA3 (220/270~GHz) beams. We fit two-dimensional elliptical Gaussians to each detector’s beam, derive per-pair differential parameters (differential pointing, beamwidth, and ellipticity). The resulting high-signal-to-noise array-averaged beam maps are used to compute the beam window function $B_l$ for the power spectrum analysis, while the individual per-detector beams feed dedicated beam convolution simulations used to validate the temperature-to-polarization (T$rightarrow$ P) deprojection procedure. After correcting for the chopper aperture, the recovered beamwidths follow the expected $lambda/D$ ordering. We also describe two pipeline improvements carried out during the 2026 campaign: an out-and-back jackknife for noise quantification and an elnod-based gain calibration.arXiv:2608.25012v1 Announce Type: new
Abstract: BICEP Array (BA) is the current-generation instrument in the BICEP series of small-aperture, on-axis refracting telescopes at the South Pole, designed to constrain the tensor-to-scalar ratio $r$ through degree-scale measurements of B-mode polarization in the cosmic microwave background (CMB). As BA pushes to deeper sensitivity, control of instrumental systematics, and beam shape mismatch between the co-located orthogonally polarized detectors in particular, has become an increasingly important factor in translating raw sensitivity into a robust constraint on $r$. In these proceedings we report on the 2026 far field beam mapping (FFBM) campaign, which used a thermal chopped source to characterize the BA2 (150~GHz) and BA3 (220/270~GHz) beams. We fit two-dimensional elliptical Gaussians to each detector’s beam, derive per-pair differential parameters (differential pointing, beamwidth, and ellipticity). The resulting high-signal-to-noise array-averaged beam maps are used to compute the beam window function $B_l$ for the power spectrum analysis, while the individual per-detector beams feed dedicated beam convolution simulations used to validate the temperature-to-polarization (T$rightarrow$ P) deprojection procedure. After correcting for the chopper aperture, the recovered beamwidths follow the expected $lambda/D$ ordering. We also describe two pipeline improvements carried out during the 2026 campaign: an out-and-back jackknife for noise quantification and an elnod-based gain calibration.
2026-08-27
Comments are closed, but trackbacks and pingbacks are open.