Opening the low-background and high-spectral-resolution domain with the ATHENA large X-ray observatory: Development of the Cryogenic AntiCoincidence Detector for the X-ray Integral Field Unit. (arXiv:1904.03307v1 [astro-ph.IM])
<a href="http://arxiv.org/find/astro-ph/1/au:+DAndrea_M/0/1/0/all/0/1">Matteo D'Andrea</a>
ATHENA is a large-class ESA mission selected for launch in 2031. It is
designed to address the science theme “The Hot and Energetic Universe”,
performing X-ray observations (0.2-12 keV) at the L2 Sun-Earth Lagrangian
point. The X-IFU is one of the two instruments of the payload. It is a
cryogenic spectrometer providing spatially resolved high-resolution
spectroscopy. The core of the instrument is a large array of TES
microcalorimeters, operated at a 50 mK thermal bath. The X-IFU performances
would be strongly degraded by the particle background expected in the L2
environment, thus advanced reduction techniques have been adopted to reduce
this contribution by a factor $sim$50. This is needed to enable many core
science objectives of the mission. Most of the background reduction ($sim
80%$) is achieved thanks to the Cryogenic AntiCoincidence detector (CryoAC), a
4 pixels TES microcalorimeter which will be placed less than 1 mm below the TES
array. The CryoAC is a sort of instrument-inside-the-instrument, with
independent cold and warm electronics and a dedicated data processing chain. To
reach the required particle rejection efficiency ($sim 98 %$) it will have a
wide energy band (from 20 keV to $sim$ 1 MeV) and a low deadtime ($< sim
2%$), while respecting several constraints to ensure mechanical, thermal and
electromagnetic compatibility with the TES array. Here I will report my PhD
research activity, which has been focused on the development of the CryoAC
Demonstration Model (DM), a single pixel detector requested by ESA before the
mission adoption. The thesis is divided in two main parts. In the first one I
will mainly present the astrophysical framework of my research, and in the
second one I will focus on the experimental activities carried out towards the
CryoAC DM development.
ATHENA is a large-class ESA mission selected for launch in 2031. It is
designed to address the science theme “The Hot and Energetic Universe”,
performing X-ray observations (0.2-12 keV) at the L2 Sun-Earth Lagrangian
point. The X-IFU is one of the two instruments of the payload. It is a
cryogenic spectrometer providing spatially resolved high-resolution
spectroscopy. The core of the instrument is a large array of TES
microcalorimeters, operated at a 50 mK thermal bath. The X-IFU performances
would be strongly degraded by the particle background expected in the L2
environment, thus advanced reduction techniques have been adopted to reduce
this contribution by a factor $sim$50. This is needed to enable many core
science objectives of the mission. Most of the background reduction ($sim
80%$) is achieved thanks to the Cryogenic AntiCoincidence detector (CryoAC), a
4 pixels TES microcalorimeter which will be placed less than 1 mm below the TES
array. The CryoAC is a sort of instrument-inside-the-instrument, with
independent cold and warm electronics and a dedicated data processing chain. To
reach the required particle rejection efficiency ($sim 98 %$) it will have a
wide energy band (from 20 keV to $sim$ 1 MeV) and a low deadtime ($< sim
2%$), while respecting several constraints to ensure mechanical, thermal and
electromagnetic compatibility with the TES array. Here I will report my PhD
research activity, which has been focused on the development of the CryoAC
Demonstration Model (DM), a single pixel detector requested by ESA before the
mission adoption. The thesis is divided in two main parts. In the first one I
will mainly present the astrophysical framework of my research, and in the
second one I will focus on the experimental activities carried out towards the
CryoAC DM development.